Volume 15, Number 2 (Iranian Journal of Physics Research,summer( proceedings ) 2015)                   IJPR 2015, 15(2): 183-188 | Back to browse issues page



DOI: 10.18869/acadpub.ijpr.15.2.183

XML Persian Abstract Print


Download citation:
BibTeX | RIS | EndNote | Medlars | ProCite | Reference Manager | RefWorks
Send citation to:

Sadeghipanah A, Sarhadi K, Rahighi J. Design and construction of a pre-injector for the Iranian Light Source Facility. IJPR. 2015; 15 (2) :183-188
URL: http://ijpr.iut.ac.ir/article-1-1839-en.html

Iranian Light Source Facility (ILSF), Institute for Research in Fundamental Sciences (IPM) , arash.sadeghipanah@gmail.com
Abstract:   (2716 Views)
Every synchrotron accelerator requires a pre-injector for primary injection of the electrons into the booster ring. The Iranian Light Source Facility (ILSF) pre-injector is a 150 MeV S-band linear accelerator with a thermionic cathode RF gun. The design of the pre-injector lattice and its beam dynamics calculation results together with the design of RF gun, alpha magnet, quadrupole magnets and linear accelerator structures are described in this article. The measurement results of the RF gun prototype fabricated in Iran demonstrate a dimension error less than 20 μm and a surface roughness of less than 0.8 μm
Full-Text [PDF 607 kb]   (693 Downloads)    
Type of Study: Research | Subject: General