<?xml version="1.0" encoding="UTF-8"?>
<!DOCTYPE ArticleSet PUBLIC "-//NLM//DTD PubMed 2.7//EN" "https://dtd.nlm.nih.gov/ncbi/pubmed/in/PubMed.dtd">
<ArticleSet>
<Article>
<Journal>
				<PublisherName>The Physics Society of Iran</PublisherName>
				<JournalTitle>Iranian Journal of Physics Research</JournalTitle>
				<Issn>1682-6957</Issn>
				<Volume>15</Volume>
				<Issue>2</Issue>
				<PubDate PubStatus="epublish">
					<Year>2019</Year>
					<Month>11</Month>
					<Day>26</Day>
				</PubDate>
			</Journal>
<ArticleTitle>Beamlines for Iranian Light Source Facility</ArticleTitle>
<VernacularTitle>Beamlines for Iranian Light Source Facility</VernacularTitle>
			<FirstPage>197</FirstPage>
			<LastPage>204</LastPage>
			<ELocationID EIdType="pii">1138</ELocationID>
			
<ELocationID EIdType="doi">10.18869/acadpub.ijpr.15.2.197</ELocationID>
			
			<Language>FA</Language>
<AuthorList>
<Author>
					<FirstName>A</FirstName>
					<LastName>Gholampour Azhir</LastName>
<Affiliation></Affiliation>

</Author>
<Author>
					<FirstName>S</FirstName>
					<LastName>Amiri</LastName>
<Affiliation></Affiliation>

</Author>
<Author>
					<FirstName>H</FirstName>
					<LastName>Khosroabadi</LastName>
<Affiliation></Affiliation>

</Author>
<Author>
					<FirstName>J</FirstName>
					<LastName>Rahighi</LastName>
<Affiliation></Affiliation>

</Author>
<Author>
					<FirstName>M</FirstName>
					<LastName>Lamehi Rachti</LastName>
<Affiliation></Affiliation>

</Author>
</AuthorList>
				<PublicationType>Journal Article</PublicationType>
			<History>
				<PubDate PubStatus="received">
					<Year>2019</Year>
					<Month>11</Month>
					<Day>26</Day>
				</PubDate>
			</History>
		<Abstract>This paper describes day-one beamlines of the Iranian Light Source Facility and design concept of powder diffraction and spectromicroscopy beamlines as the most priorities of each synchrotron that cover the research requirements in the fields of physics, chemistry, nano-science, etc. For powder diffraction beamline energy range is 6-30 keV, resolution: 10-4, flux: 1012(ph/s/0.1%B.W.) and spot size at sample is 0.1×0.1-1×10 mm2. For spectromicroscopy beamline energy range is 90-2500 eV, flux: 3×1015(ph/s/0.1%B.W.@96eV), resolving power of 1820 at 1000 eV and spot size at sample is 4×2-27×74 µm2</Abstract>
			<OtherAbstract Language="FA">This paper describes day-one beamlines of the Iranian Light Source Facility and design concept of powder diffraction and spectromicroscopy beamlines as the most priorities of each synchrotron that cover the research requirements in the fields of physics, chemistry, nano-science, etc. For powder diffraction beamline energy range is 6-30 keV, resolution: 10-4, flux: 1012(ph/s/0.1%B.W.) and spot size at sample is 0.1×0.1-1×10 mm2. For spectromicroscopy beamline energy range is 90-2500 eV, flux: 3×1015(ph/s/0.1%B.W.@96eV), resolving power of 1820 at 1000 eV and spot size at sample is 4×2-27×74 µm2</OtherAbstract>
		<ObjectList>
			<Object Type="keyword">
			<Param Name="value">beamline</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">Powder diffraction</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">spectromicroscopy</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">X-ray optics</Param>
			</Object>
		</ObjectList>
<ArchiveCopySource DocType="pdf">https://ijpr.iut.ac.ir/article_1138_c3e0c62ee91db8dc7382bde7419bb573.pdf</ArchiveCopySource>
</Article>
</ArticleSet>
