<?xml version="1.0" encoding="UTF-8"?>
<!DOCTYPE ArticleSet PUBLIC "-//NLM//DTD PubMed 2.7//EN" "https://dtd.nlm.nih.gov/ncbi/pubmed/in/PubMed.dtd">
<ArticleSet>
<Article>
<Journal>
				<PublisherName>The Physics Society of Iran</PublisherName>
				<JournalTitle>Iranian Journal of Physics Research</JournalTitle>
				<Issn>1682-6957</Issn>
				<Volume>9</Volume>
				<Issue>4</Issue>
				<PubDate PubStatus="epublish">
					<Year>2019</Year>
					<Month>11</Month>
					<Day>26</Day>
				</PubDate>
			</Journal>
<ArticleTitle>Calibration constant of a silver activation counter used with plasma focus devices</ArticleTitle>
<VernacularTitle>Calibration constant of a silver activation counter used with plasma focus devices</VernacularTitle>
			<FirstPage>305</FirstPage>
			<LastPage>312</LastPage>
			<ELocationID EIdType="pii">835</ELocationID>
			
			
			<Language>FA</Language>
<AuthorList>
<Author>
					<FirstName>GR</FirstName>
					<LastName>Etaati</LastName>
<Affiliation></Affiliation>
<Identifier Source="ORCID">0000-0003-3544-4560</Identifier>

</Author>
<Author>
					<FirstName>R</FirstName>
					<LastName>Amrollahi</LastName>
<Affiliation></Affiliation>

</Author>
<Author>
					<FirstName>V</FirstName>
					<LastName>Doostmohammadi</LastName>
<Affiliation></Affiliation>

</Author>
</AuthorList>
				<PublicationType>Journal Article</PublicationType>
			<History>
				<PubDate PubStatus="received">
					<Year>2019</Year>
					<Month>11</Month>
					<Day>26</Day>
				</PubDate>
			</History>
		<Abstract>The silver activation counters are commonly used for pulsed-neutron yield measurements especially in plasma focus devices. The counter normally consists of a Geiger-Muller tube along with silver foils and polyethylene (as a moderator), which is calibrated against an Am-Be radioisotope neutron source. The neutrons, after being slowed-down in the polyethylene, activate the silver foils. By measuring the foil activity with a Geiger-Muller counter, the neutron yield is determined. In the present paper, the activation counter’s calibration constant calculation using the MCNP4C code is explained. The calculated calibration constant is in good agreement with the experimental results.</Abstract>
			<OtherAbstract Language="FA">The silver activation counters are commonly used for pulsed-neutron yield measurements especially in plasma focus devices. The counter normally consists of a Geiger-Muller tube along with silver foils and polyethylene (as a moderator), which is calibrated against an Am-Be radioisotope neutron source. The neutrons, after being slowed-down in the polyethylene, activate the silver foils. By measuring the foil activity with a Geiger-Muller counter, the neutron yield is determined. In the present paper, the activation counter’s calibration constant calculation using the MCNP4C code is explained. The calculated calibration constant is in good agreement with the experimental results.</OtherAbstract>
		<ObjectList>
			<Object Type="keyword">
			<Param Name="value">silver activation counter</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">plasma focus</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">MCNP4C Code</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">calibration constant</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">neutron</Param>
			</Object>
		</ObjectList>
<ArchiveCopySource DocType="pdf">https://ijpr.iut.ac.ir/article_835_4d5b995358e7798bc7e9d9db83c612a5.pdf</ArchiveCopySource>
</Article>
</ArticleSet>
