Volume 17, Issue 2 (Iranian Journal of Physics Research ( proceedings ) 2017)                   IJPR 2017, 17(2): 177-184 | Back to browse issues page


XML Persian Abstract Print


Download citation:
BibTeX | RIS | EndNote | Medlars | ProCite | Reference Manager | RefWorks
Send citation to:

Pirani S, Sarhadi K, Moradi V, Kamkari B, Dehghani J, Rahighi J. Designing 100 MHZ Cavity for Iranian Light Source Facility storage ring. IJPR. 2017; 17 (2) :177-184
URL: http://ijpr.iut.ac.ir/article-1-2393-en.html

Iranian Light Source Facility (ILSF), Institute for Research in Fundamental Sciences (IPM), Tehran, Iran , saeid.pirani@ipm.ir
Abstract:   (1164 Views)
Iranian Light Source Facility (ILSF) RF system was conceptually designed based on ILSF requirements for a 3 GeV storage ring and 400 mA beam current at 500 MHz RF frequency. Considering the fact that  cavity construction is simpler at 100 MHz and advantages of reducing frequency provided an alternative of 100MHz RF system to be explored for ILSF. After a thorough study on the effect of reducing RF frequency on electron beam, machine parameters and comparison of RF systems at both frequencies, the RF frequency was switched to 100 MHz. This paper presents these investigations and comparision leading to selecting the intended frequency. Furthermore, the electromagnetic and mechanical design for 100 MHz cavity are discussed.
 
 
Full-Text [PDF 12 kb]   (221 Downloads)    

 
Type of Study: Research | Subject: General

Add your comments about this article : Your username or Email:
Write the security code in the box

Send email to the article author


© 2015 All Rights Reserved | Iranian Journal of Physics Research

Designed & Developed by : Yektaweb

تحت نظارت وف بومی آسپا-وف