Authors

Abstract

Investigation of Hydrocarbon reservoir is important, so it is essential to predict and explore them precisely. One of the methods is well logging, which can transfer the probe or tool in the well to measure one or more characteristics. Nuclear well logging includes radioisotope source and at least one detector. In this work, emission direction of neutrons from the 241Am-Be neutron source toward the calcite formation has been investigated using MCNPX 2.6 to obtain the best precision in determining the liquid porosity. The results show that emission direction of 20 in degree with the resolution porosity of 3% in counts is recorded in detectors; as well; there is no decrease in depth penetration, providing speed of tools.

Keywords

2. P Parvaresh and M Sohrabpour, Journal of Radioanalytical and Nuclear Chemistry 260, 2 (2004) 335.
3. J Tittman, H Sherman, W A Nagel, and R P Alger, Journal of Petroleum Technology 18, 10 (1966) 1351.
4. R P Alger, S Locke, W A Nagel, and H Sherman, Journal of Petroleum Technology 24, 9 (1979) 1073.